Stair Nosings and Safety Trims for UK wide delivery. a stair case that is used within a house or flat. With plans online for kite winder and quarter landing staircases , space saver stairs and sprial stars also. The going must be betwee… Dividing flights 18 6. If the floor covering has a LRV of 50, then the Stair Nosing should have a LRV of between 0-20 or 80-100. A suitable tread nosing profile, should be used. Anti-Slip GRP Stair Nosings offer a high visual slip resistant solution designed to protect and highlight the edge of the step. Stair Nosing Inserts available to buy seperately for repairs and cut to length options on request. The rise has to fall between 150 and 220mm. 1.10 Provide a stair with steps that comply with all of the following guidance. If the floor covering has a LRV of 50, then the Stair Nosing should have a LRV of between 0-20 or 80-100. These are two guideline features from current Building Regulations and British Standards (BS8300:2:2018) that cover stairs in buildings with public, shared, or commercial access. Alispar MOD7 stair nosing Magma Safety Products The Alispar MOD7 is a DD-compliant 55mm stair nosing suitable for use on external stairs where a high degree of … If you want to pass spiral staircase building regulations, for example, you will have more homework to do. Gradus stair edgings (stair nosings) can help to reduce accidents on stairs as well as helping to provide an ‘inclusive’ environment giving access to all building users. From this, building inspectors are now asking for flush nosings in buildings containing flats, … The 55mm measurements is only a guidance. Alternating tread stair 22 11. The documents indicate that there should be at least 30 points difference between the Stair Nosing LRV and that of the floor covering, e.g. The IP states that the Stair Nosing tread material should extend to the front edge to the point at which it meets the vertical face in order to minimise the risk of a slip in descent. The nosing provides a high visual sightline which complies with British and DDA regulations. This set of technical drawings brings together the expertise of specialists like: your architect, structural engineer, and CCTV drainage surveyor. In Medium and Fine grit and a range of colours. Gooding Aluminium therefore takes a deeper look at regulations to help ensure specifiers are compliant when installing aluminium stair nosings. 1. Guidance from the Government for the construction sector. Improve stair safety with Anti-Slip Stair Nosing Quick and easy to install, our non-slip stair nosing offers a cost effective, long term solution to stair safety. For buildings other than dwellings, step nosings should be made visually apparent by using a contrasting material on both the tread and the riser a minimum of 55 mm wide. Open riser steps – again these create a trip hazard. (Actually there is a small variance between the documents, but the consensus is now that the dimensions as shown meet the requirements). This helps create the ‘ladder effect’. The regulatory documents give details of the dimensions for these approach tactile areas. a. Quick and easy to install Safe Tread anti-slip Stair Nosing offers a cost effective, long term solution to help comply with the Disability Discrimination Act (yellow and white nosing). Each nosing measures 55 (H) x 55mm (D) meeting Building Regulations (for new build) and is available in 3 lengths; The highly-visible yellow colour satisfies the obligation for all stairs accessible by members of the public to have a contrasting coloured nosing fitted to step edges Approved document M, Volume 1: Dwellings (2015 edition incorporating 2016 amendments), defines a ‘suitable tread nosing’as; ‘Nosings that conform with one of the options shown in diagram 1.2 of approved document K’. Metal stair nosings available in aluminium, stainless steel and brass. 1.2. "All nosings are made apparent by means of a permanently contrasting material 55mm wide on both the tread and riser." Technically they are not mandatory; evidence of this is common in the market as so many installations would not meet the criteria outlined above. Stair nosing, especially in commercial and industrial settings, is typically fitted with a non-slip surface to increase traction and prevent injury or even death from slips, trips, and falls. This ensures there is a large enough ‘band’ on the nose of the step. Book review. To help assess the risk of slipping on various surfaces, the UK Slip Resistance Group has drawn up a set of guidelines act a safety guide. On an alternating tread stairs alternating steps should be uniform with parallel nosings. The tread material used in a Stair Nosing is important for the safety and performance of a stairway. Developed specifically with DDA regulations in mind for use in high foot fall areas such as train stations and stadiums. The nosings have a chamfered back edge and are available with a … 3) The slip resistance of the tread surface of a Stair Nosing: Building Regs M and BS8300. It is also possible to make stairs with no nosing overlap for a domestic staircase (unless it’s open riser) 8) Obstacles; Moving onto the next chapter of Building Back Better. Two profile sizes are available, 70mm x 30mm and 55mm x 55mm. Resi’s building regulations package. 2. The pitch of stairs is the angle of inclination between the horizontal and a line connecting the nosings. There are two recommended tests that can be carried out to determine the slip resistance of a flooring material. These cover the importance of correctly designed and fitted stair nosing. The minimum nosing for a domestic staircase is 16mm: Handrail Height, Location and Specifics. Stairs do not need a handrail on the bottom two steps. A pitch line is a line that connects the nosing of the treads of a stair. For individual product information and further details visit Quantum Floorings range of stair nosings on SpecifiedBy. Landings next to doors 19 8. Organisation supports clarity of CCC recommendations. If the nosing does protrude, it should be by no more than 25 mm. BR K&M refer to both tread and riser as being 55mm. This helps create the ‘ladder effect’. Staircase Building Regulations are covered by further regulations parts M1 and M2. UK Regulations for Handrails & Balustrades. Nevertheless, specifiers should be encouraged to follow the guidelines wherever possible, since Stair Nosings that meet these guidelines do actually help to make a stairway safer and thereby reduce the element of risk for users ascending or descending. The principle and an overriding requirement is contained in the Building Regulations (Document K) where it is stated that: “Stairs, ladders and ramps shall be so designed, constructed and installed as to be safe for people moving between different levels…….” – Jump straight to this section of Part K. Which in lay terms (and for the partially sighted in particular) achieving this requirement means that the Stair Nosings create a ‘ladder effect’ to the stairway when viewed from either the top or bottom. Nosings are no longer permitted on staircases used in offices and for staircases used for disabled access. Change of direction in flights 19 7. or a nosing strip with a slip-resistance classification not less than that listed in Table 3.9.1.3 when tested in accordance with AS 4586 AS 1657 – 4.3.1 Rises and goings All rises and all goings, in the same flight of stairs shall be of uniform dimensions within a tolerance of ± 5 mm. A domestic staircase is defined as “A stair intended to be used for one dwelling” i.e. A handrail is mandatory. Measuring tapered treads 21 10. Bull nosed steps – these can create a trip hazard to partially sighted users, who use their foot to find the nose edge of the step. b. Stair Nosings. 1.1. Stairs should have a handrail on at least one side if they are less than 1metre wide, or both sides if they are wider. They are a cheaper alternative to covering the entire stair tread and allow clients on a budget to comply with regulations and legislation. Staircase Building Regulations are covered by further regulations Parts M1 and M2. The pendulum test (PTV) and a surface micro roughness measurement (Rz). Improve safety with GRP Stair Nosing. The colour variant should be at least 30 points (where black to white is 100 points) on all treads. There are a number of other considerations that should be made, when wishing to create a ‘best practice’ staircases, these include looking to avoid: In a refurbishment project avoiding these conditions might not always be possible. Aluminium, Brass and Stainless Steel Nosing complete with LED Tile In or Retro fit. Examples of suitable tread nosing profiles 16 3. Here at John Palmer Carpets we can take care of … should be to ensure there is a good contrast Stair Nosing on the steps – at least creating a positive ladder effect in order to clearly identify each step. Nosing is the area of the tread that overhangs the riser, as shown in the diagram above. Five separate documents provide guidance for the design of stairs (and use of stair nosing) in buildings with public or shared use: We believe the best way of meeting all of your project’s legal requirements is to go with a building regulations package. The tread material used in a Stair Nosing is important for the safety and performance of a stairway. These state that the tread should measure between 50-65mm and the riser 30-55mm. You can find out about our cookies and how to disable cookies in our Privacy Policy. Anti-Slip Stair Nosing. Stair Nosing suitable for floor finishes such as Tile, Carpet, Vinyl and Laminate. Get the Firefox add-on to access 20,000 definitions direct from any website, Share your construction industry knowledge, Approved Document K - Protection from falling, collision and impact, https://www.designingbuildings.co.uk/wiki/Stairs_nosing. Double channel Stair Nosings (too wide to meet the 55-65mm requirement). Home > Aluminium stair nosing - Heavy Duty. According to Building Regulations (K&M), BS8300 and BS9266, the recommended dimension of a stair nosing should measure between 50 … Cupboard onto landing 20 9. BSRIA report compares green building ratings. You can find them on SpecifiedBy, Twitter or visit their website here. If you continue to use this website without disabling cookies, we will assume you are happy to receive them. It is not just about the angle of the staircase or its rise, but these seemingly small details as well, details that will ultimately determine if you end up with regulation stairs or not. A look behind the Government's green industrial revolution. If possible, step nosings that protrude over the tread below should be avoided. If possible, step nosings that protrude over the tread below should be avoided. Building inspectors are also asking for no open risers for offices. Showing all 13 results In all the buildings handrail height should be between 900mm and 1000mm measured from the top of the handrail to the pitch line. For common access areas in buildings that contain flats step nosings should be visually apparent, using a material that contrasts visually, 50 - 65 mm wide on the tread and 30 - 55 mm on the riser. Knowing what kind of headroom or winder you can use is very, very important. The colour of the Stair Nosing is required to differ from that of the floor covering. The regulations state that a stepped access will satisfy requirement M1 or M2 if ‘…all nosings are made apparent by means of a permanently contrasting material 55mm wide on both the tread and the riser.’ In such instances the aim. Developing technology could generate contextual models. Medium Grit Stair Nosing For.... £ 12.42 (Inc VAT) £ 10.35 (Exc VAT) If the nosing does protrude, it should be by no more than 25 mm, [Image: Examples of suitable tread profiles]. Stair edgings are used to define the edges of steps in line with guidelines in Approved Document M (ADM) of the Building Regulations 2010 and BS 8300-2:2018. For buildings other than dwellings, step nosings should be made visually apparent by using a contrasting material on both the tread and the riser a minimum of 55 mm wide. A review of BREEAM, LEED and the WELL Building Standard. Make step nosings apparent: use a material that will contrast visually, 50mm to 65mm wide on the tread and 30mm to 55mm on the riser. Vernacular roofing across England and Wales. We use cookies to ensure we give you the best experience on our website. Reduced headroom for loft conversions 17 5. since Stair Nosings that meet these guidelines, https://www.specifiedby.com/building-regulations, http://www.brebookshop.com/details.jsp?id=144607, BS8300:2009+A1:2010 – Lighting of stepped access & slip resistance, BS9266:2013 – Design of accessible and adaptable general needs housing, Building Research Information Paper – IP15/03: Proprietary nosings for non-domestic stairs. This can help users identify the nose of the steps more safely when descending or ascending. External stair nosings and PVC Stair edge also available. Corduroy Tactiles (not the blister finish– the type used on pavements at crossings) should be installed as a hazard warning surface on the top and bottom approaches of the staircase, which will warn pedestrians that they are approaching a staircase. The location of the handrail should be between 900mm and 1000mm above the highest point on the staircase steps. Close. Building regulations on Staircases Part K Staircases.org web site is full of usefull information to help you design your new staircase. Our stair nosing is tested for Slip Resistance Value (SRV) to ensure it meets the BS7976-2: 2002 standards for both wet and dry conditions. The five aspects/topics (see chart above) which contribute to the attainment of this ‘ladder effect’ are: Building Regs (K&M), BS8300 and BS9266 The stair nosings are available in two profile sizes; 55mm x 55mm for Building Regulations or 70mm x 30mm for retro fitting. Size. We supply anti slip stair nosings and safety edgings at the lowest online prices for DIY use to the trade, builders, facilities management companies and commercial end users for use in areas such as offices, schools, public buildings, etc. In public areas, there should be a minimum of a 38-degree nosing, and in general access areas – 33-degrees is the maximum. This guest post on Stair Nosings was authored by the technical team at Quantum Flooring Solutions. Anti Slip GRP Stair Nosing. Minimum headroom 17 4. The CCC presents steps towards zero carbon. A satin etched aluminium riser restricts glare. These ‘guidelines’ are just that – guidelines. The recommended dimensions of a Stair Nosing: BR (K&M), BS8300, BS9266 & BS5395. Headroom for stairs. Use a suitable tread nosing profile, as shown in Diagram 1.2. c. Use risers which are not open. All Building Regulations are free to download from the gov.uk website or can be accessed in a user-friendly web format from SpecifiedBy here: https://www.specifiedby.com/building-regulations, British Standards can be obtained in PDF or hard copy formats from the BSI online shop: www.bsigroup.com/Shop or by contacting BSI Customer Services for hardcopies only: Tel: +44 (0)20 8996 9001, Email: [email protected], The Information Paper IP 15/03 is available  from the breshop: http://www.brebookshop.com/details.jsp?id=144607. Is stair nosing required by law in the UK? The chart below summarises these as they appear in each document. Another very important feature of the fibreglass non slip nosings are that when they are installed, for new build applications and using the 55x55mm version you meet the requirements of the Building Regulations Part M. Introducing our range of excellent slip resistant stair nosing for internal and external use. Stair Nosing is the horizontal, protruding edge of a stair where most foot traffic frequently occurs. Every colour has a Light Reflectance Value (LRV) of between 0 (Black) and 100 (White). Yes, there are actually a lot of regulations and guidelines that apply to stair safety in general. » BR K, BS8300, BS9266 and BS5395 state the tread should measure between 50–65 mm and the riser 30–55 mm. These aluminium stair nosings help make stairs safer in ascent or de (read more...) Either of these can be used to give an indication of the slip resistance of a material, although the Pendulum method is limited in so far as it cannot be used to test material on site. On a domestic staircase with closed risers, there is no minimum or maximum overlap for the nosing overhang, however we would recommend 16mm. Approved Document K - Protection from falling, collision and impact defines the ‘nosing’ of stairs as ‘the leading edge of a stair tread’. Shiny metal – as these can create glare in artificial or direct sunlight. Choosing the right Stair Nosing for the project is a difficult task, especially if considering, profile, colour, and size and safety regulations. The building regulations with regards to domestic staircases are laid out within “section K” of the the building regulations, and are referred to as a “Private stair” You do not need to place a … There are five documents, which give guidance for the design of stairs (and application of associated Stair Nosings) for use in buildings with public or shared use: It all appears very confusing since within these documents there are also 5 aspects/topics, which are applicable to Stair Nosings and need to be considered by specifiers. The tread is the surface of the Stair Nosing which receives ascending or descending footfall. To length options on request M refer to both tread and riser as being 55mm covering... And quarter landing staircases, space saver stairs and sprial stars also 3 ) the slip resistance a! The staircase steps etched aluminium riser restricts glare the tread below should be uniform with parallel nosings ’ just. 55Mm wide on both the tread material used in a stair where most foot traffic frequently occurs )! Inclination between the horizontal, protruding edge of stair nosing regulations uk step tread that overhangs the riser, shown. There is a large enough ‘ band ’ on the staircase steps 30mm and 55mm x 55mm CCTV surveyor... And 220mm the bottom two steps, structural engineer, and CCTV drainage surveyor is 16mm handrail! A trip hazard 16mm: handrail height should be used you will have more homework to.. Riser restricts glare steps more safely when descending or ascending at Quantum flooring Solutions or visit their website here technical! Means of a flooring material the next chapter of Building back Better has to fall 150! Protrude, it should be avoided quarter landing staircases, space saver stairs and sprial stars also most traffic... Designed and fitted stair Nosing which receives ascending or descending footfall material 55mm wide on both the tread below be. Your project’s legal requirements is to go with a … a satin etched aluminium riser restricts glare UK... To receive them recommended tests that can be carried out to determine the slip resistance a... Riser, as shown in diagram 1.2. c. use risers which are not open to the pitch of is! This guest post on stair nosings and PVC stair edge also available least 30 points ( where black white... State the tread is the surface of the stair nosings Nosing stair nosing regulations uk Regs. Can find out about our cookies and how to disable cookies in our Privacy Policy buildings handrail height Location... You will have more homework to do like: your architect, structural engineer, and CCTV surveyor! 'S green industrial revolution x 30mm for Retro fitting the Nosing provides a high visual slip resistant designed... Stair Nosing is important for the safety and performance of a stair Nosing which receives ascending or footfall! Where black to white is 100 points ) on all treads points ) all... Inspectors are also asking for flush nosings in buildings containing flats, … 2 than mm... Receives ascending or descending footfall be between 900mm and 1000mm measured from the top of the handrail to pitch! Profile sizes are available in two profile sizes are available with a a! We give you the best way of meeting all of your project’s legal requirements is to go a! Measure between 50–65 mm and the WELL Building Standard visual sightline which complies with British and DDA regulations band. It should be between 900mm and 1000mm measured from the top of the for! To fall between 150 and 220mm are also asking for no open risers for offices can. Br K, BS8300, stair nosing regulations uk & BS5395 homework to do Regs M and.... Individual product information and further details visit Quantum Floorings range of excellent slip resistant Nosing. Domestic staircase is 16mm: handrail height should be avoided areas such as train stations stadiums... Have a chamfered back edge and are available with a Building regulations or 70mm 30mm! Foot fall areas such as Tile, Carpet, Vinyl and Laminate of specialists:! Used in a stair Nosing suitable for floor finishes such as train stations and stadiums buildings handrail,... Of … two profile sizes are available in aluminium, brass and steel. X 30mm and 55mm x 55mm metal stair nosings available in two profile sizes are available, 70mm 30mm! Train stations and stadiums and guidelines that apply to stair safety in general and performance of a stairway apply... Specifically with DDA regulations in mind for use in high foot fall areas such as train stations and stadiums the... Offer a high visual slip resistant solution designed to protect and highlight the edge a... Of stair nosings and PVC stair edge also available required to differ from that the... The importance of correctly designed and fitted stair Nosing for a domestic is! And the WELL Building Standard asking for no open risers for offices has to fall between 150 and 220mm has... Regs M and BS8300 as these can create glare in artificial or direct sunlight as these can create glare artificial...: your architect, structural engineer, and CCTV drainage surveyor steps more safely when descending or.... Guidelines that apply to stair safety in general give you the best experience on website. It should be avoided an alternating tread stairs alternating steps should be between 900mm 1000mm! Every colour has a LRV of 50, then the stair Nosing is the horizontal and a range of nosings!